Product Description P/N: IFP-50
Description
The Silent Knight IFP-50 replacement board is the main control board for the IFP-50 intelligent analog/addressable fire alarm control panel. It manages the panel’s SLC loop, notification appliance circuits, communications, programmable relays, system accessories, and addressable detection functions.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | Silent Knight |
| Category | Fire Alarm Systems |
| Part Number | IFP-50 |
| Subcategory | Fire Alarm Control Boards |
| Product Type | Replacement Fire Alarm Control Board |
| System Platform | IFP-50 Intelligent Fire Alarm Control Panel |
| SLC Loops | 1 |
| Addressable Device Capacity | Up to 50 Hochiki devices or 50 IDP detectors and 50 IDP modules |
| SLC Configuration | Class B Style 4; Class A Style 6 or Style 7 |
| Notification Appliance Circuits | 2 programmable circuits |
| NAC Rating | Up to 2.5 A per circuit at 27.4 VDC |
| Communication Interfaces | RS-485 and RS-232 |
| Programmable Relays | 2 Form C relays, 2.5 A at 24 VDC |
| Trouble Relay | Form C, 2.5 A at 24 VDC |
| Event History | Up to 1,000 events |
| Software Zones | 125 |
| Output Groups | 125 |
| Operating Temperature | 32°F to 120°F (0°C to 49°C) |
| Operating Humidity | 10% to 93% RH, non-condensing |
| Weight | 11 lb |
Information About IFP-50
The IFP-50 is a replacement control board for the Silent Knight IFP-50 intelligent fire alarm control panel platform. The system provides a single signaling line circuit supporting up to 50 Hochiki devices or a combination of up to 50 IDP detectors and 50 IDP modules. Its architecture supports Class A and Class B SLC configurations, two programmable notification appliance circuits, RS-485 accessory communication, RS-232 programming, and integrated digital communication functions. Built-in processing provides detector sensitivity adjustment, day/night thresholds, drift compensation, maintenance alerts, event storage, software zoning, and automatic system programming.
Key Features:
- Addressable SLC Support: Controls one signaling line circuit for compatible Hochiki or Silent Knight IDP addressable devices.
- Device Capacity: Supports up to 50 Hochiki devices or up to 50 IDP detectors plus 50 IDP modules.
- Flexible SLC Wiring: Supports Class B Style 4 and Class A Style 6 or Style 7 signaling line circuit configurations.
- Dual NAC Control: Provides two programmable notification appliance circuits supporting notification or auxiliary power functions.
- Integrated Communications: Supports built-in digital communication for remote reporting and system programming.
- Programmable Relays: Includes a Form C trouble relay and two programmable Form C relays rated at 2.5 A at 24 VDC.
- System Interfaces: Incorporates RS-485 accessory communication and an RS-232 interface for PC-based programming.
- Intelligent Processing: Supports detector sensitivity settings, day/night thresholds, drift compensation, automatic sensitivity testing, and maintenance alerts.
The IFP-50 delivers the reliability and precision required for addressable detection, notification, communication, and control within compatible Silent Knight IFP-50 fire alarm systems.
Description
The Silent Knight IFP-50 replacement board is the main control board for the IFP-50 intelligent analog/addressable fire alarm control panel. It manages the panel’s SLC loop, notification appliance circuits, communications, programmable relays, system accessories, and addressable detection functions.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | Silent Knight |
| Category | Fire Alarm Systems |
| Part Number | IFP-50 |
| Subcategory | Fire Alarm Control Boards |
| Product Type | Replacement Fire Alarm Control Board |
| System Platform | IFP-50 Intelligent Fire Alarm Control Panel |
| SLC Loops | 1 |
| Addressable Device Capacity | Up to 50 Hochiki devices or 50 IDP detectors and 50 IDP modules |
| SLC Configuration | Class B Style 4; Class A Style 6 or Style 7 |
| Notification Appliance Circuits | 2 programmable circuits |
| NAC Rating | Up to 2.5 A per circuit at 27.4 VDC |
| Communication Interfaces | RS-485 and RS-232 |
| Programmable Relays | 2 Form C relays, 2.5 A at 24 VDC |
| Trouble Relay | Form C, 2.5 A at 24 VDC |
| Event History | Up to 1,000 events |
| Software Zones | 125 |
| Output Groups | 125 |
| Operating Temperature | 32°F to 120°F (0°C to 49°C) |
| Operating Humidity | 10% to 93% RH, non-condensing |
| Weight | 11 lb |
Information About IFP-50
The IFP-50 is a replacement control board for the Silent Knight IFP-50 intelligent fire alarm control panel platform. The system provides a single signaling line circuit supporting up to 50 Hochiki devices or a combination of up to 50 IDP detectors and 50 IDP modules. Its architecture supports Class A and Class B SLC configurations, two programmable notification appliance circuits, RS-485 accessory communication, RS-232 programming, and integrated digital communication functions. Built-in processing provides detector sensitivity adjustment, day/night thresholds, drift compensation, maintenance alerts, event storage, software zoning, and automatic system programming.
Key Features:
- Addressable SLC Support: Controls one signaling line circuit for compatible Hochiki or Silent Knight IDP addressable devices.
- Device Capacity: Supports up to 50 Hochiki devices or up to 50 IDP detectors plus 50 IDP modules.
- Flexible SLC Wiring: Supports Class B Style 4 and Class A Style 6 or Style 7 signaling line circuit configurations.
- Dual NAC Control: Provides two programmable notification appliance circuits supporting notification or auxiliary power functions.
- Integrated Communications: Supports built-in digital communication for remote reporting and system programming.
- Programmable Relays: Includes a Form C trouble relay and two programmable Form C relays rated at 2.5 A at 24 VDC.
- System Interfaces: Incorporates RS-485 accessory communication and an RS-232 interface for PC-based programming.
- Intelligent Processing: Supports detector sensitivity settings, day/night thresholds, drift compensation, automatic sensitivity testing, and maintenance alerts.
The IFP-50 delivers the reliability and precision required for addressable detection, notification, communication, and control within compatible Silent Knight IFP-50 fire alarm systems.