Product Description P/N: SK-6324
Description
The Silent Knight SK-6324 is a six-zone, 24VDC conventional fire alarm control panel designed for small to mid-size installations. It includes six Class B initiating circuits, a 2.5A power supply, three supervised notification appliance circuits, and dedicated alarm and trouble relays for reliable and efficient fire protection control.
Technical Specifications
Condition | New/Never Used Surplus |
Brand | Silent Knight |
Category | Fire Alarm Equipment |
Part Number | SK-6324 |
Subcategory | Fire Alarm Control Panel |
Type | Conventional FACP |
Number of Zones | Six Class B zones |
Operating Voltage | 24 VDC |
Power Supply | 2.5A integral power supply |
Notification Circuits | Three Class B circuits, 2.5A max combined output |
Relay Outputs | Dedicated alarm and trouble relays |
Auxiliary Power Output | 0.5A max for accessories (e.g., door holders or remote devices) |
Enhanced Verification Mode | Differentiates between pull stations and smoke detectors |
Compatibility | Supports 2-wire and 4-wire smoke detectors, manual pull stations, and heat detectors |
Supervision | Full supervision on input and output circuits |
Enclosure Material | Steel housing with hinged access door |
Mounting Type | Wall-mounted panel enclosure |
System Type | Local conventional fire alarm control |
Dimensions | 14 × 12 × 3 in |
Weight | 2 lbs |
Certifications | UL Listed, NFPA 72 compliant |
Applications | Commercial buildings, schools, small facilities, and industrial sites |
Information About SK-6324
The SK-6324 is part of Silent Knight’s line of reliable, easy-to-install conventional fire alarm control panels. It offers six Class B initiating zones for connection of smoke detectors, heat detectors, and manual pull stations, making it ideal for small to medium fire protection systems. Its integrated 2.5A power supply provides ample capacity for notification appliances and auxiliary devices. The panel also includes three supervised notification appliance circuits (NACs), along with dedicated alarm and trouble relays for integration with external systems. Featuring an Enhanced Verification Mode, the SK-6324 can differentiate between a smoke detector signal and a manual pull activation, reducing false alarms. Its compact, durable design and intuitive wiring layout make it well-suited for professional installations.
Key Features
- Six Supervised Class B Zones: Supports multiple initiating devices for comprehensive detection coverage.
- Integrated 2.5A Power Supply: Provides stable power for system operation and notification appliances.
- Three Notification Circuits: Each supervised output rated for up to 2.5A maximum combined load.
- Auxiliary Power Output: Supplies up to 0.5A for accessories such as door holders or external modules.
- Enhanced Verification Mode: Built-in feature distinguishes between smoke detector and manual pull station activations.
- Dedicated Relays: Alarm and trouble relays ensure clear signaling and system status reporting.
- Versatile Device Compatibility: Works with 2-wire and 4-wire smoke detectors and other conventional devices.
- Durable Construction: Compact steel enclosure designed for reliability and service longevity.
The SK-6324 delivers the reliability and precision required for smaller fire alarm systems, providing efficient supervision, flexible configuration, and robust power distribution in one compact package.
Description
The Silent Knight SK-6324 is a six-zone, 24VDC conventional fire alarm control panel designed for small to mid-size installations. It includes six Class B initiating circuits, a 2.5A power supply, three supervised notification appliance circuits, and dedicated alarm and trouble relays for reliable and efficient fire protection control.
Technical Specifications
Condition | New/Never Used Surplus |
Brand | Silent Knight |
Category | Fire Alarm Equipment |
Part Number | SK-6324 |
Subcategory | Fire Alarm Control Panel |
Type | Conventional FACP |
Number of Zones | Six Class B zones |
Operating Voltage | 24 VDC |
Power Supply | 2.5A integral power supply |
Notification Circuits | Three Class B circuits, 2.5A max combined output |
Relay Outputs | Dedicated alarm and trouble relays |
Auxiliary Power Output | 0.5A max for accessories (e.g., door holders or remote devices) |
Enhanced Verification Mode | Differentiates between pull stations and smoke detectors |
Compatibility | Supports 2-wire and 4-wire smoke detectors, manual pull stations, and heat detectors |
Supervision | Full supervision on input and output circuits |
Enclosure Material | Steel housing with hinged access door |
Mounting Type | Wall-mounted panel enclosure |
System Type | Local conventional fire alarm control |
Dimensions | 14 × 12 × 3 in |
Weight | 2 lbs |
Certifications | UL Listed, NFPA 72 compliant |
Applications | Commercial buildings, schools, small facilities, and industrial sites |
Information About SK-6324
The SK-6324 is part of Silent Knight’s line of reliable, easy-to-install conventional fire alarm control panels. It offers six Class B initiating zones for connection of smoke detectors, heat detectors, and manual pull stations, making it ideal for small to medium fire protection systems. Its integrated 2.5A power supply provides ample capacity for notification appliances and auxiliary devices. The panel also includes three supervised notification appliance circuits (NACs), along with dedicated alarm and trouble relays for integration with external systems. Featuring an Enhanced Verification Mode, the SK-6324 can differentiate between a smoke detector signal and a manual pull activation, reducing false alarms. Its compact, durable design and intuitive wiring layout make it well-suited for professional installations.
Key Features
- Six Supervised Class B Zones: Supports multiple initiating devices for comprehensive detection coverage.
- Integrated 2.5A Power Supply: Provides stable power for system operation and notification appliances.
- Three Notification Circuits: Each supervised output rated for up to 2.5A maximum combined load.
- Auxiliary Power Output: Supplies up to 0.5A for accessories such as door holders or external modules.
- Enhanced Verification Mode: Built-in feature distinguishes between smoke detector and manual pull station activations.
- Dedicated Relays: Alarm and trouble relays ensure clear signaling and system status reporting.
- Versatile Device Compatibility: Works with 2-wire and 4-wire smoke detectors and other conventional devices.
- Durable Construction: Compact steel enclosure designed for reliability and service longevity.
The SK-6324 delivers the reliability and precision required for smaller fire alarm systems, providing efficient supervision, flexible configuration, and robust power distribution in one compact package.