SNAC-6 | Gamewell-FCI Supplementary Notification Appliance Circuit Panel, 6A Output
SNAC-6 | Gamewell-FCI Supplementary Notification Appliance Circuit Panel, 6A Output
SNAC-6 | Gamewell-FCI Supplementary Notification Appliance Circuit Panel, 6A Output
    SNAC-6 | Gamewell-FCI Supplementary Notification Appliance Circuit Panel, 6A Output
SNAC-6 | Gamewell-FCI Supplementary Notification Appliance Circuit Panel, 6A Output

SNAC-6 | Gamewell-FCI Supplementary Notification Appliance Circuit Panel, 6A Output

Part #: SNAC-6 Manufactured by: Gamewell-FCI
Regular price
$1,699.00
Sale price
$1,699.00
Regular price
1 in Stock
Condition: New-Surplus Original Box
Shipping calculated at checkout.
Product Overview
The SNAC-6 is a supplementary NAC panel that boosts notification appliance capacity with up to 6 amps of output, synchroni...  Read more
We accept:
  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa
warranty
IQElectro 2-Year Warranty
Warranty for Product #: SNAC-6
IQElectro offers a free 2-year warranty on all products. You can trust that every purchase is a reliable investment in the future of your company. Warranty Terms
2-3 Day Free Shipping
Packed Ready to Ship
24/7 Expert Support
Return within 30-Days
IQElectro LLC BBB Business Review
IQElectro is Not an authorized distributor for Gamewell-FCI
Original Manufacturer's Warranty Not Covered, This Product is SURPLUS.

Product Description P/N: SNAC-6

Description / Specifications

Description 

The Gamewell-FCI SNAC-6 is a supplementary notification appliance circuit panel that provides up to 6 amps of power across multiple Class A or Class B circuits. It integrates with existing notification appliance circuits, offering synchronization, temporal pattern outputs, and full supervision for reliable fire alarm signaling.

 

 

Technical Specifications 

Condition New/Never Used Surplus
Brand Gamewell-FCI
Category Fire Alarm Systems
Part Number SNAC-6
Subcategory NAC Panels
Type Supplementary notification appliance circuit panel
Output Capacity 6 A total
Output Circuits 2 Class A (Style Z), 4 Class B (Style Y), or 1 Class A + 2 Class B
Input Source 1 or 2 existing Class A/B NACs
Operating Voltage 9–32 VDC
Operation Modes Coded or non-coded
Temporal Pattern Programmable ANSI S3.41 temporal Class B output from non-coded input
Synchronization Built-in sync for strobes from 3 manufacturers
Ground Fault Detection Integral supervision with ground fault detection
Trouble Reporting Form “C” contacts, delayed AC failure indication
Compliance UL Listed fire alarm accessory
Applications Expands NAC capacity for FCI and other UL Listed fire alarm systems
Dimensions 16.00 × 12.25 × 3.00 in
Weight 6.5 lbs

 


Information About SNAC-6

The SNAC-6 is a UL Listed supplementary notification appliance circuit panel engineered to expand the signaling capabilities of fire alarm systems. It provides up to 6 amps of regulated output that can be distributed across Class A or Class B circuits, depending on installation needs. With the ability to synchronize strobes from three leading manufacturers, it ensures consistent visual signaling across facilities. Additional features include ANSI S3.41 temporal pattern outputs, coded/non-coded operation, ground fault detection, and Form “C” trouble contacts. Designed for compatibility with Gamewell-FCI and other UL Listed control panels, the SNAC-6 enhances both capacity and reliability in life safety applications.

Key Features:

  • High current output: Provides 6 amps of total NAC power for supporting multiple notification appliances.
  • Flexible circuit configuration: Supports 2 Class A, 4 Class B, or mixed 1 Class A and 2 Class B circuits to fit system requirements.
  • Input circuit integration: Activates through one or two existing Class A or B notification appliance circuits for seamless expansion.
  • Coded and non-coded operation: Allows flexible control options, including compatibility with coded inputs.
  • Programmable temporal outputs: Provides ANSI S3.41-compliant temporal Class B outputs from non-coded inputs.
  • Strobe synchronization: Features built-in synchronization for appliances from three major manufacturers.
  • Supervised operation: Equipped with ground fault detection to ensure circuit integrity.
  • Trouble monitoring: Includes Form “C” trouble contacts with delayed AC failure indication for enhanced system reporting.
  • UL Listed accessory: Approved for use with Gamewell-FCI and other UL Listed fire alarm systems.
  • Durable enclosure: Measures 16 × 12.25 × 3 inches and weighs 6.5 lbs for dependable installation.

The SNAC-6 delivers the reliability and precision required for expanding NAC capacity and synchronization in commercial and institutional fire alarm systems.

IQElectro is not an authorized distributor.
IQElectro LLC (IQElectro) is NOT an Authorized Distributor or in any way affiliated with Rockwell Automation, Siemens, or any other Manufacturers. IQElectro is NOT an Authorized Dealer of this product. The product may be of older version, date codes, or design than that available from authorized dealers. As IQElectro is not an authorized dealer of this product, the Original Manufacturer's Warranty and Support DO NOT apply. IQElectro sells SURPLUS only and DOES NOT SELL SOFTWARE or FIRMWARE licenses For more detailed information, please refer to the full version of our disclaimer policy Disclaimer Policy.
Description / Specifications

Description 

The Gamewell-FCI SNAC-6 is a supplementary notification appliance circuit panel that provides up to 6 amps of power across multiple Class A or Class B circuits. It integrates with existing notification appliance circuits, offering synchronization, temporal pattern outputs, and full supervision for reliable fire alarm signaling.

 

 

Technical Specifications 

Condition New/Never Used Surplus
Brand Gamewell-FCI
Category Fire Alarm Systems
Part Number SNAC-6
Subcategory NAC Panels
Type Supplementary notification appliance circuit panel
Output Capacity 6 A total
Output Circuits 2 Class A (Style Z), 4 Class B (Style Y), or 1 Class A + 2 Class B
Input Source 1 or 2 existing Class A/B NACs
Operating Voltage 9–32 VDC
Operation Modes Coded or non-coded
Temporal Pattern Programmable ANSI S3.41 temporal Class B output from non-coded input
Synchronization Built-in sync for strobes from 3 manufacturers
Ground Fault Detection Integral supervision with ground fault detection
Trouble Reporting Form “C” contacts, delayed AC failure indication
Compliance UL Listed fire alarm accessory
Applications Expands NAC capacity for FCI and other UL Listed fire alarm systems
Dimensions 16.00 × 12.25 × 3.00 in
Weight 6.5 lbs

 


Information About SNAC-6

The SNAC-6 is a UL Listed supplementary notification appliance circuit panel engineered to expand the signaling capabilities of fire alarm systems. It provides up to 6 amps of regulated output that can be distributed across Class A or Class B circuits, depending on installation needs. With the ability to synchronize strobes from three leading manufacturers, it ensures consistent visual signaling across facilities. Additional features include ANSI S3.41 temporal pattern outputs, coded/non-coded operation, ground fault detection, and Form “C” trouble contacts. Designed for compatibility with Gamewell-FCI and other UL Listed control panels, the SNAC-6 enhances both capacity and reliability in life safety applications.

Key Features:

  • High current output: Provides 6 amps of total NAC power for supporting multiple notification appliances.
  • Flexible circuit configuration: Supports 2 Class A, 4 Class B, or mixed 1 Class A and 2 Class B circuits to fit system requirements.
  • Input circuit integration: Activates through one or two existing Class A or B notification appliance circuits for seamless expansion.
  • Coded and non-coded operation: Allows flexible control options, including compatibility with coded inputs.
  • Programmable temporal outputs: Provides ANSI S3.41-compliant temporal Class B outputs from non-coded inputs.
  • Strobe synchronization: Features built-in synchronization for appliances from three major manufacturers.
  • Supervised operation: Equipped with ground fault detection to ensure circuit integrity.
  • Trouble monitoring: Includes Form “C” trouble contacts with delayed AC failure indication for enhanced system reporting.
  • UL Listed accessory: Approved for use with Gamewell-FCI and other UL Listed fire alarm systems.
  • Durable enclosure: Measures 16 × 12.25 × 3 inches and weighs 6.5 lbs for dependable installation.

The SNAC-6 delivers the reliability and precision required for expanding NAC capacity and synchronization in commercial and institutional fire alarm systems.

Check Out These Related Products

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)