Square D PJA36080U33A PJA Molded Case Circuit Breaker
- Regular price
- $10,792.00
- Sale price
- $10,792.00
- Regular price
-
Couldn't load pickup availability
Product Description P/N: PJA36080U33A
Description
Square D PJA36080U33A is a PJA-series molded case circuit breaker designed for high-capacity commercial and industrial electrical distribution systems. It uses a MicroLogic 5.0 electronic trip unit with true RMS sensing and adjustable long-time, short-time, and instantaneous protection.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | Square D |
| Category | Circuit Protection |
| Part Number | PJA36080U33A |
| Subcategory | Molded Case Circuit Breaker |
| Series | PJA |
| Rated Current | 800A |
| Current Range | 320–800A |
| Number of Poles | 3 |
| Phase | 3 |
| Voltage Rating | 240VAC, 480VAC, 600VAC |
| Trip Technology | Electronic |
| Trip Unit | MicroLogic 5.0 |
| Trip Function | LSI – Long-Time, Short-Time, Instantaneous |
| Trip Adjustability | Adjustable |
| Sensing Technology | True RMS |
| Interrupting Rating at 240VAC | 100kA |
| Interrupting Rating at 480VAC | 65kA |
| Interrupting Rating at 600VAC | 25kA |
| Continuous Current Rating | 80% |
| Mounting Style | I-Line |
| Terminal Type | Lugs |
| Wire Range | (3) 3/0 AWG–500 kcmil Al/Cu |
| Compatible Equipment | I-Line Panelboards & Switchboards |
| Construction | Interchangeable Trip Unit |
| Application | HACR Rated, Power Distribution |
| Standards | UL 489, CSA C22.2 No. 5, IEC 60947-2, NEMA AB 1 |
| Approvals | CE, CSA, IEC, NOM, UL |
| Operating Temperature | -25°C to 70°C |
| Weight | 32 lbs |
Information About PJA36080U33A
Key Features:
- Electronic Trip Protection: Provides electronic overcurrent protection with true RMS sensing.
- MicroLogic 5.0 Trip Unit: Uses an adjustable electronic trip system for circuit protection.
- LSI Protection: Provides long-time, short-time, and instantaneous trip functions.
- Adjustable Settings: Allows protection characteristics to be configured for the application.
- I-Line Mounting: Designed for installation in compatible Square D I-Line equipment.
- Interchangeable Trip Unit: Supports service and configuration flexibility within compatible systems.
- High Interrupting Capacity: Designed for demanding commercial and industrial distribution applications.
- Accessory Support: Compatible with auxiliary switches, shunt trips, undervoltage releases, motor operators, and communication modules.
The PJA36080U33A delivers the adjustable electronic circuit protection required for compatible Square D I-Line power distribution systems.
Description
Square D PJA36080U33A is a PJA-series molded case circuit breaker designed for high-capacity commercial and industrial electrical distribution systems. It uses a MicroLogic 5.0 electronic trip unit with true RMS sensing and adjustable long-time, short-time, and instantaneous protection.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | Square D |
| Category | Circuit Protection |
| Part Number | PJA36080U33A |
| Subcategory | Molded Case Circuit Breaker |
| Series | PJA |
| Rated Current | 800A |
| Current Range | 320–800A |
| Number of Poles | 3 |
| Phase | 3 |
| Voltage Rating | 240VAC, 480VAC, 600VAC |
| Trip Technology | Electronic |
| Trip Unit | MicroLogic 5.0 |
| Trip Function | LSI – Long-Time, Short-Time, Instantaneous |
| Trip Adjustability | Adjustable |
| Sensing Technology | True RMS |
| Interrupting Rating at 240VAC | 100kA |
| Interrupting Rating at 480VAC | 65kA |
| Interrupting Rating at 600VAC | 25kA |
| Continuous Current Rating | 80% |
| Mounting Style | I-Line |
| Terminal Type | Lugs |
| Wire Range | (3) 3/0 AWG–500 kcmil Al/Cu |
| Compatible Equipment | I-Line Panelboards & Switchboards |
| Construction | Interchangeable Trip Unit |
| Application | HACR Rated, Power Distribution |
| Standards | UL 489, CSA C22.2 No. 5, IEC 60947-2, NEMA AB 1 |
| Approvals | CE, CSA, IEC, NOM, UL |
| Operating Temperature | -25°C to 70°C |
| Weight | 32 lbs |
Information About PJA36080U33A
Key Features:
- Electronic Trip Protection: Provides electronic overcurrent protection with true RMS sensing.
- MicroLogic 5.0 Trip Unit: Uses an adjustable electronic trip system for circuit protection.
- LSI Protection: Provides long-time, short-time, and instantaneous trip functions.
- Adjustable Settings: Allows protection characteristics to be configured for the application.
- I-Line Mounting: Designed for installation in compatible Square D I-Line equipment.
- Interchangeable Trip Unit: Supports service and configuration flexibility within compatible systems.
- High Interrupting Capacity: Designed for demanding commercial and industrial distribution applications.
- Accessory Support: Compatible with auxiliary switches, shunt trips, undervoltage releases, motor operators, and communication modules.
The PJA36080U33A delivers the adjustable electronic circuit protection required for compatible Square D I-Line power distribution systems.