Product Description P/N: THQC1120GF
Description
The THQC1120GF is a single-pole, 20 Amp GFCI circuit breaker from GE, offering thermal magnetic protection and ground fault interruption. It features a plug-in design and is rated for 120 V systems with a 10 kAIC interrupting capacity.
Technical Specifications
Condition | New/Never Used Surplus |
---|---|
Brand | General Electric |
Category |
Circuit Breaker
|
Part Number | THQC1120GF |
Subcategory | Panel Mount Circuit Breaker |
Series | THQC |
Amperage | 20 A |
Voltage Rating | 120 V |
Number of Poles | 1 |
Phase | Single-phase |
Interrupting Capacity | 10 kAIC at 120 V |
Protection Type | Thermal Magnetic |
Trip Functions | LI (Long-Time and Instantaneous) |
Circuit Breaker Type | GFCI |
Frame Type | THQC |
Connection Type | Plug-In |
Certification | UL Listed |
Weight | 0.53 lbs |
Information About THQC1120GF
The THQC1120GF is part of GE's THQC series and delivers reliable thermal-magnetic circuit protection with integrated ground fault circuit interruption (GFCI) for enhanced safety. Designed for single-phase, 1-pole applications at 120 volts, this breaker is suited for protecting personnel and equipment in residential and commercial systems. With a 20 Amp rating, it supports lighting, outlet, and general load circuits while monitoring leakage current to ground. The plug-in frame type allows fast installation into compatible load centers, and the unit supports LI tripping functions (Long-Time and Instantaneous) for overload and short-circuit response. It meets UL certification and handles up to 10 kAIC at 120 V, ensuring robust performance in standard protection environments.
Key Features:
- Ground Fault Circuit Interruption (GFCI): Integrated GFCI function protects against electrical shock hazards by detecting ground leakage current, essential for wet or high-risk environments.
- Thermal Magnetic Protection: Built-in long-time and instantaneous tripping mechanisms respond to overloads and short circuits, preserving system safety and preventing damage.
- Compact Single-Pole Design: Rated for 120 V single-phase systems and sized for minimal space in panelboards or load centers, suitable for residential and light commercial use.
- High Interrupting Capacity: With a 10 kAIC rating at 120 V, this breaker can safely interrupt significant fault currents without system failure or hazard.
- Plug-In Mounting: Designed for easy and secure installation into compatible THQC load centers, reducing labor time and ensuring stable electrical connections.
The THQC1120GF combines personnel protection, circuit integrity, and compact installation, making it an ideal solution for GFCI-required branch circuits.
Description
The THQC1120GF is a single-pole, 20 Amp GFCI circuit breaker from GE, offering thermal magnetic protection and ground fault interruption. It features a plug-in design and is rated for 120 V systems with a 10 kAIC interrupting capacity.
Technical Specifications
Condition | New/Never Used Surplus |
---|---|
Brand | General Electric |
Category |
Circuit Breaker
|
Part Number | THQC1120GF |
Subcategory | Panel Mount Circuit Breaker |
Series | THQC |
Amperage | 20 A |
Voltage Rating | 120 V |
Number of Poles | 1 |
Phase | Single-phase |
Interrupting Capacity | 10 kAIC at 120 V |
Protection Type | Thermal Magnetic |
Trip Functions | LI (Long-Time and Instantaneous) |
Circuit Breaker Type | GFCI |
Frame Type | THQC |
Connection Type | Plug-In |
Certification | UL Listed |
Weight | 0.53 lbs |
Information About THQC1120GF
The THQC1120GF is part of GE's THQC series and delivers reliable thermal-magnetic circuit protection with integrated ground fault circuit interruption (GFCI) for enhanced safety. Designed for single-phase, 1-pole applications at 120 volts, this breaker is suited for protecting personnel and equipment in residential and commercial systems. With a 20 Amp rating, it supports lighting, outlet, and general load circuits while monitoring leakage current to ground. The plug-in frame type allows fast installation into compatible load centers, and the unit supports LI tripping functions (Long-Time and Instantaneous) for overload and short-circuit response. It meets UL certification and handles up to 10 kAIC at 120 V, ensuring robust performance in standard protection environments.
Key Features:
- Ground Fault Circuit Interruption (GFCI): Integrated GFCI function protects against electrical shock hazards by detecting ground leakage current, essential for wet or high-risk environments.
- Thermal Magnetic Protection: Built-in long-time and instantaneous tripping mechanisms respond to overloads and short circuits, preserving system safety and preventing damage.
- Compact Single-Pole Design: Rated for 120 V single-phase systems and sized for minimal space in panelboards or load centers, suitable for residential and light commercial use.
- High Interrupting Capacity: With a 10 kAIC rating at 120 V, this breaker can safely interrupt significant fault currents without system failure or hazard.
- Plug-In Mounting: Designed for easy and secure installation into compatible THQC load centers, reducing labor time and ensuring stable electrical connections.
The THQC1120GF combines personnel protection, circuit integrity, and compact installation, making it an ideal solution for GFCI-required branch circuits.