THQL21100 | General Electric THQL Series Two-Pole Circuit Breaker 100A 120/240V 10kAIC
- Regular price
- $64.00
- Sale price
- $64.00
- Regular price
-
Couldn't load pickup availability
Do you need help?
Product Description P/N: THQL21100
Description
The General Electric THQL21100 is a two-pole circuit breaker rated at 100 amps for branch and feeder circuit protection in residential electrical systems. Manufactured by General Electric, part number THQL21100 is designed for plug-in installation in compatible Q-Line load centers and supports 120/240 volt operation.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | General Electric |
| Category | Circuit Breaker |
| Part Number | THQL21100 |
| Subcategory | App/Comm Circuit Breaker |
| Amperage Rating | 100 A |
| Voltage Rating | 120/240 V |
| Number of Poles | 2 |
| Phase | Single-phase |
| Interrupting Capacity | 10 kAIC |
| Trip Function | LI |
| Trip Style | Non-Interchangeable |
| Frame Type | Q-Line |
| Mounting Type | Plug-In |
| Continuous Current Rating | Standard |
| Long Time Trip | Fixed |
| Instantaneous Trip | Fixed |
| Suitable for Reverse Feed | Yes |
| Special Markings | HACR |
| Protective Relays | No |
| Current Metering | No |
| GSA Compliance | Yes |
| Dimensions | 3 in H × 2 in W × 3 in L |
| Alternate Part Number | THQL2100 |
Information About THQL21100
The THQL21100 is part of the General Electric THQL Series, representing the standard-size breaker family used in Q-Line residential panelboards. It features a compact two-pole design intended for single-phase systems operating at 120/240 volts. The breaker integrates directly into compatible plug-in load centers, supporting straightforward installation and system expansion. Typical applications include residential feeder and branch circuits where dependable thermal-magnetic protection and code compliance are required.
Key Features
- THQL Series Construction: Designed as part of GE’s standard Q-Line breaker family for residential load centers.
- 100 Amp Two-Pole Rating: Provides coordinated protection for higher-capacity 120/240V circuits.
- Plug-In Mounting Design: Enables fast installation and secure electrical connection in compatible panels.
- Thermal-Magnetic Trip Unit: Combines long-time overload protection with instantaneous short-circuit response.
- 10 kAIC Interrupt Rating: Safely interrupts fault currents up to 10,000 amperes.
- HACR Rated: Suitable for heating, air conditioning, and refrigeration circuit applications.
- Compact Standard Form Factor: Optimized dimensions ensure compatibility with residential panelboard layouts.
The THQL21100 delivers the reliability and precision required for residential feeder and branch circuit protection in General Electric Q-Line electrical distribution systems.
Description
The General Electric THQL21100 is a two-pole circuit breaker rated at 100 amps for branch and feeder circuit protection in residential electrical systems. Manufactured by General Electric, part number THQL21100 is designed for plug-in installation in compatible Q-Line load centers and supports 120/240 volt operation.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | General Electric |
| Category | Circuit Breaker |
| Part Number | THQL21100 |
| Subcategory | App/Comm Circuit Breaker |
| Amperage Rating | 100 A |
| Voltage Rating | 120/240 V |
| Number of Poles | 2 |
| Phase | Single-phase |
| Interrupting Capacity | 10 kAIC |
| Trip Function | LI |
| Trip Style | Non-Interchangeable |
| Frame Type | Q-Line |
| Mounting Type | Plug-In |
| Continuous Current Rating | Standard |
| Long Time Trip | Fixed |
| Instantaneous Trip | Fixed |
| Suitable for Reverse Feed | Yes |
| Special Markings | HACR |
| Protective Relays | No |
| Current Metering | No |
| GSA Compliance | Yes |
| Dimensions | 3 in H × 2 in W × 3 in L |
| Alternate Part Number | THQL2100 |
Information About THQL21100
The THQL21100 is part of the General Electric THQL Series, representing the standard-size breaker family used in Q-Line residential panelboards. It features a compact two-pole design intended for single-phase systems operating at 120/240 volts. The breaker integrates directly into compatible plug-in load centers, supporting straightforward installation and system expansion. Typical applications include residential feeder and branch circuits where dependable thermal-magnetic protection and code compliance are required.
Key Features
- THQL Series Construction: Designed as part of GE’s standard Q-Line breaker family for residential load centers.
- 100 Amp Two-Pole Rating: Provides coordinated protection for higher-capacity 120/240V circuits.
- Plug-In Mounting Design: Enables fast installation and secure electrical connection in compatible panels.
- Thermal-Magnetic Trip Unit: Combines long-time overload protection with instantaneous short-circuit response.
- 10 kAIC Interrupt Rating: Safely interrupts fault currents up to 10,000 amperes.
- HACR Rated: Suitable for heating, air conditioning, and refrigeration circuit applications.
- Compact Standard Form Factor: Optimized dimensions ensure compatibility with residential panelboard layouts.
The THQL21100 delivers the reliability and precision required for residential feeder and branch circuit protection in General Electric Q-Line electrical distribution systems.