Part #: THQL2130 Manufactured by: General Electric
Regular price
$49.00
Sale price
$49.00
Regular price
4 in Stock
Condition: New-Surplus Original Box
Shipping calculated at checkout.
Product Overview
THQL2130, General Electric, type THQL, 2P, 1PH, 30A, 240V, 10kA@120V, UL listed, Plug-In, complete with LI - Long-Time and...  Read more
We accept:
  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa
warranty
IQElectro 2-Year Warranty
Warranty for Product #: THQL2130
IQElectro offers a free 2-year warranty on all products. You can trust that every purchase is a reliable investment in the future of your company. Warranty Terms
2-3 Day Free Shipping
Packed Ready to Ship
24/7 Expert Support
Return within 30-Days
IQElectro is Not an authorized distributor for General Electric
Original Manufacturer's Warranty Not Covered, This Product is SURPLUS.

Product Description P/N: THQL2130

Description / Specifications

Description 

The General Electric THQL2130 is a 30-amp, 240-volt double-pole molded case circuit breaker designed for residential and light commercial load centers. It provides thermal-magnetic protection to safeguard circuits from overloads and short-circuit conditions. With a plug-in connection and standard 10 kA interrupt rating, the THQL2130 supports reliable installation and fault interruption performance.

 

 

Technical Specifications 

Condition New/Never Used Surplus
Brand General Electric
Category Circuit Breaker
Part Number THQL2130
Subcategory Load Center Circuit Breaker
Family Q-Line
Type THQL
Voltage Rating 240 V
Amperage Rating 30 A
Phase 1-Phase
Number of Poles 2
Protection Type Thermal Magnetic
Trip Functions LI – Long-Time and Instantaneous
AIC Rating 10 kA @ 120 V
Connection Type Plug-In
Terminal Type Load-side lug terminals
Application Residential and light commercial branch-circuit protection
Mounting Style Load center plug-in
Special Features Suitable for reverse feed applications

 

 

Information About THQL2130

The THQL2130 is part of GE’s Q-Line Series, a family of load center breakers engineered for dependable overcurrent protection. Its molded case design and plug-in construction allow quick replacement and secure engagement within compatible panelboards. The two-pole configuration supports 240-volt circuits or dual-circuit protection, making it suitable for medium-load residential applications. Equipped with LI trip functions and thermal-magnetic sensing technology, the breaker offers responsive and comprehensive fault protection.

Key Features:

  • Q-Line Series design: Compatible with GE load centers for residential and light commercial use.
  • 30A, 240V rating: Supports medium-load branch circuit applications.
  • Thermal-magnetic trip: Provides overload and instantaneous short-circuit protection.
  • Plug-in connection: Enables fast and secure installation.
  • Two-pole configuration: Suitable for 240-volt loads or dual-circuit protection.
  • 10 kA interrupt rating: Meets standard fault-level protection requirements.
  • LI trip functions: Offers long-time and instantaneous protection characteristics.
  • Reverse feed capable: Supports installation flexibility for certain panel configurations.

The THQL2130 delivers the reliability and precision required for molded case circuit protection in residential and light commercial power systems.

IQElectro is not an authorized distributor.
IQElectro LLC (IQElectro) is NOT an Authorized Distributor or in any way affiliated with Rockwell Automation, Siemens, or any other Manufacturers. IQElectro is NOT an Authorized Dealer of this product. The product may be of older version, date codes, or design than that available from authorized dealers. As IQElectro is not an authorized dealer of this product, the Original Manufacturer's Warranty and Support DO NOT apply. IQElectro sells SURPLUS only and DOES NOT SELL SOFTWARE or FIRMWARE licenses For more detailed information, please refer to the full version of our disclaimer policy Disclaimer Policy.
Description / Specifications

Description 

The General Electric THQL2130 is a 30-amp, 240-volt double-pole molded case circuit breaker designed for residential and light commercial load centers. It provides thermal-magnetic protection to safeguard circuits from overloads and short-circuit conditions. With a plug-in connection and standard 10 kA interrupt rating, the THQL2130 supports reliable installation and fault interruption performance.

 

 

Technical Specifications 

Condition New/Never Used Surplus
Brand General Electric
Category Circuit Breaker
Part Number THQL2130
Subcategory Load Center Circuit Breaker
Family Q-Line
Type THQL
Voltage Rating 240 V
Amperage Rating 30 A
Phase 1-Phase
Number of Poles 2
Protection Type Thermal Magnetic
Trip Functions LI – Long-Time and Instantaneous
AIC Rating 10 kA @ 120 V
Connection Type Plug-In
Terminal Type Load-side lug terminals
Application Residential and light commercial branch-circuit protection
Mounting Style Load center plug-in
Special Features Suitable for reverse feed applications

 

 

Information About THQL2130

The THQL2130 is part of GE’s Q-Line Series, a family of load center breakers engineered for dependable overcurrent protection. Its molded case design and plug-in construction allow quick replacement and secure engagement within compatible panelboards. The two-pole configuration supports 240-volt circuits or dual-circuit protection, making it suitable for medium-load residential applications. Equipped with LI trip functions and thermal-magnetic sensing technology, the breaker offers responsive and comprehensive fault protection.

Key Features:

  • Q-Line Series design: Compatible with GE load centers for residential and light commercial use.
  • 30A, 240V rating: Supports medium-load branch circuit applications.
  • Thermal-magnetic trip: Provides overload and instantaneous short-circuit protection.
  • Plug-in connection: Enables fast and secure installation.
  • Two-pole configuration: Suitable for 240-volt loads or dual-circuit protection.
  • 10 kA interrupt rating: Meets standard fault-level protection requirements.
  • LI trip functions: Offers long-time and instantaneous protection characteristics.
  • Reverse feed capable: Supports installation flexibility for certain panel configurations.

The THQL2130 delivers the reliability and precision required for molded case circuit protection in residential and light commercial power systems.