Product Description P/N: THQL2130
Description
The General Electric THQL2130 is a 30-amp, 240-volt double-pole molded case circuit breaker designed for residential and light commercial load centers. It provides thermal-magnetic protection to safeguard circuits from overloads and short-circuit conditions. With a plug-in connection and standard 10 kA interrupt rating, the THQL2130 supports reliable installation and fault interruption performance.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | General Electric |
| Category | Circuit Breaker |
| Part Number | THQL2130 |
| Subcategory | Load Center Circuit Breaker |
| Family | Q-Line |
| Type | THQL |
| Voltage Rating | 240 V |
| Amperage Rating | 30 A |
| Phase | 1-Phase |
| Number of Poles | 2 |
| Protection Type | Thermal Magnetic |
| Trip Functions | LI – Long-Time and Instantaneous |
| AIC Rating | 10 kA @ 120 V |
| Connection Type | Plug-In |
| Terminal Type | Load-side lug terminals |
| Application | Residential and light commercial branch-circuit protection |
| Mounting Style | Load center plug-in |
| Special Features | Suitable for reverse feed applications |
Information About THQL2130
The THQL2130 is part of GE’s Q-Line Series, a family of load center breakers engineered for dependable overcurrent protection. Its molded case design and plug-in construction allow quick replacement and secure engagement within compatible panelboards. The two-pole configuration supports 240-volt circuits or dual-circuit protection, making it suitable for medium-load residential applications. Equipped with LI trip functions and thermal-magnetic sensing technology, the breaker offers responsive and comprehensive fault protection.
Key Features:
- Q-Line Series design: Compatible with GE load centers for residential and light commercial use.
- 30A, 240V rating: Supports medium-load branch circuit applications.
- Thermal-magnetic trip: Provides overload and instantaneous short-circuit protection.
- Plug-in connection: Enables fast and secure installation.
- Two-pole configuration: Suitable for 240-volt loads or dual-circuit protection.
- 10 kA interrupt rating: Meets standard fault-level protection requirements.
- LI trip functions: Offers long-time and instantaneous protection characteristics.
- Reverse feed capable: Supports installation flexibility for certain panel configurations.
The THQL2130 delivers the reliability and precision required for molded case circuit protection in residential and light commercial power systems.
Description
The General Electric THQL2130 is a 30-amp, 240-volt double-pole molded case circuit breaker designed for residential and light commercial load centers. It provides thermal-magnetic protection to safeguard circuits from overloads and short-circuit conditions. With a plug-in connection and standard 10 kA interrupt rating, the THQL2130 supports reliable installation and fault interruption performance.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | General Electric |
| Category | Circuit Breaker |
| Part Number | THQL2130 |
| Subcategory | Load Center Circuit Breaker |
| Family | Q-Line |
| Type | THQL |
| Voltage Rating | 240 V |
| Amperage Rating | 30 A |
| Phase | 1-Phase |
| Number of Poles | 2 |
| Protection Type | Thermal Magnetic |
| Trip Functions | LI – Long-Time and Instantaneous |
| AIC Rating | 10 kA @ 120 V |
| Connection Type | Plug-In |
| Terminal Type | Load-side lug terminals |
| Application | Residential and light commercial branch-circuit protection |
| Mounting Style | Load center plug-in |
| Special Features | Suitable for reverse feed applications |
Information About THQL2130
The THQL2130 is part of GE’s Q-Line Series, a family of load center breakers engineered for dependable overcurrent protection. Its molded case design and plug-in construction allow quick replacement and secure engagement within compatible panelboards. The two-pole configuration supports 240-volt circuits or dual-circuit protection, making it suitable for medium-load residential applications. Equipped with LI trip functions and thermal-magnetic sensing technology, the breaker offers responsive and comprehensive fault protection.
Key Features:
- Q-Line Series design: Compatible with GE load centers for residential and light commercial use.
- 30A, 240V rating: Supports medium-load branch circuit applications.
- Thermal-magnetic trip: Provides overload and instantaneous short-circuit protection.
- Plug-in connection: Enables fast and secure installation.
- Two-pole configuration: Suitable for 240-volt loads or dual-circuit protection.
- 10 kA interrupt rating: Meets standard fault-level protection requirements.
- LI trip functions: Offers long-time and instantaneous protection characteristics.
- Reverse feed capable: Supports installation flexibility for certain panel configurations.
The THQL2130 delivers the reliability and precision required for molded case circuit protection in residential and light commercial power systems.