Product Description P/N: THQMV175WL
Description
The General Electric THQMV175WL is a 175 A main circuit breaker designed for use in 150–225 A PowerMark Gold load centers. This plug-in breaker provides LI (long-time and instantaneous) protection through a thermal magnetic trip unit to safeguard single-phase electrical systems. Engineered for reliable performance, the THQMV175WL supports dependable power distribution in residential and commercial panel applications.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | General Electric |
| Category | Circuit Breaker |
| Part Number | THQMV175WL |
| Subcategory | App/Comm Circuit Breaker |
| Family | PowerMark Gold |
| Type | THQMV |
| Voltage Rating | 120 V |
| Amperage Rating | 175 A |
| Poles | 2 |
| Phase | 1 |
| Protection | Thermal Magnetic |
| Trip Functions | LI — Long-Time and Instantaneous |
| AIC Rating | 22 kA @ 240 V |
| Connection Type | Plug-In |
| Application | Main breaker for 150–225 A PowerMark Gold load centers |
| Mounting Method | Top-feed load center installation |
| Breaker Style | Molded Case |
Information About THQMV175WL
The THQMV175WL is part of GE’s PowerMark Gold family, a series designed for main breaker applications in compatible load centers. Built with a molded case construction and thermal magnetic trip design, the breaker ensures durable operation and consistent protection under varying load conditions. It integrates smoothly with PowerMark Gold top-feed panelboards through its plug-in mounting system, providing a secure electrical interface. Commonly used in residential and light commercial installations, the breaker’s LI trip functions and 2-pole configuration make it suitable for managing high-capacity 120 V single-phase service equipment.
Key Features:
- 175 A rating: Supports high-capacity main breaker applications.
- Plug-in connection: Allows fast installation into PowerMark Gold load centers.
- Thermal magnetic trip: Provides overload and instantaneous fault protection.
- LI trip functions: Long-time and instantaneous operating characteristics.
- 22 kA interrupt rating: Handles elevated fault levels for enhanced system safety.
- 2-pole configuration: Protects both ungrounded conductors in the system.
- PowerMark Gold compatibility: Designed specifically for 150–225 A panelboards.
The THQMV175WL delivers the reliability and precision required for main circuit protection in residential and commercial power distribution systems.
Description
The General Electric THQMV175WL is a 175 A main circuit breaker designed for use in 150–225 A PowerMark Gold load centers. This plug-in breaker provides LI (long-time and instantaneous) protection through a thermal magnetic trip unit to safeguard single-phase electrical systems. Engineered for reliable performance, the THQMV175WL supports dependable power distribution in residential and commercial panel applications.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | General Electric |
| Category | Circuit Breaker |
| Part Number | THQMV175WL |
| Subcategory | App/Comm Circuit Breaker |
| Family | PowerMark Gold |
| Type | THQMV |
| Voltage Rating | 120 V |
| Amperage Rating | 175 A |
| Poles | 2 |
| Phase | 1 |
| Protection | Thermal Magnetic |
| Trip Functions | LI — Long-Time and Instantaneous |
| AIC Rating | 22 kA @ 240 V |
| Connection Type | Plug-In |
| Application | Main breaker for 150–225 A PowerMark Gold load centers |
| Mounting Method | Top-feed load center installation |
| Breaker Style | Molded Case |
Information About THQMV175WL
The THQMV175WL is part of GE’s PowerMark Gold family, a series designed for main breaker applications in compatible load centers. Built with a molded case construction and thermal magnetic trip design, the breaker ensures durable operation and consistent protection under varying load conditions. It integrates smoothly with PowerMark Gold top-feed panelboards through its plug-in mounting system, providing a secure electrical interface. Commonly used in residential and light commercial installations, the breaker’s LI trip functions and 2-pole configuration make it suitable for managing high-capacity 120 V single-phase service equipment.
Key Features:
- 175 A rating: Supports high-capacity main breaker applications.
- Plug-in connection: Allows fast installation into PowerMark Gold load centers.
- Thermal magnetic trip: Provides overload and instantaneous fault protection.
- LI trip functions: Long-time and instantaneous operating characteristics.
- 22 kA interrupt rating: Handles elevated fault levels for enhanced system safety.
- 2-pole configuration: Protects both ungrounded conductors in the system.
- PowerMark Gold compatibility: Designed specifically for 150–225 A panelboards.
The THQMV175WL delivers the reliability and precision required for main circuit protection in residential and commercial power distribution systems.