Part #: UDA2182-CC1-NN2-NN-N-0E00-EE Manufactured by: Honeywell
Regular price
$2,045.00
Sale price
$2,045.00
Regular price
1 in Stock
Condition: New-Surplus Original Box
Shipping calculated at checkout.
Product Overview
The UDA2182-CC1-NN2-NN-N-0E00-EE is a panel-mounted conductivity analyzer with one active input channel, dual analog outpu...  Read more
We accept:
  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa
warranty
IQElectro 2-Year Warranty
Warranty for Product #: UDA2182-CC1-NN2-NN-N-0E00-EE
IQElectro offers a free 2-year warranty on all products. You can trust that every purchase is a reliable investment in the future of your company. Warranty Terms
2-3 Day Free Shipping
Packed Ready to Ship
24/7 Expert Support
Return within 30-Days
IQElectro LLC BBB Business Review
IQElectro is Not an authorized distributor for Honeywell
Original Manufacturer's Warranty Not Covered, This Product is SURPLUS.

Product Description P/N: UDA2182-CC1-NN2-NN-N-0E00-EE

Description / Specifications

Description 

The Honeywell UDA2182-CC1-NN2-NN-N-0E00-EE is a single-channel analytical analyzer designed for precise conductivity measurement in industrial liquid analysis applications. It combines digital reliability with dual current outputs and integrated alarm functions in a compact panel-mounted design.

 

 

Technical Specifications 

Condition New/Never Used Surplus
Brand Honeywell
Category
Controls & Indicators
Part Number UDA2182-CC1-NN2-NN-N-0E00-EE
Subcategory Temperature/Process Control
Series UDA2182
Analyzer Type Single Input (Contacting Conductivity)
Channel 1 Input Contacting Conductivity
Channel 2 Input
None
Outputs (2) 4–20 mA analog outputs
Alarm Relays (2) SPDT programmable alarm relays
Communications Infrared (IR) diagnostics port
Mounting Type Panel Mount
Display LCD with menu navigation
Weight 2.59 lbs

  

 

Information About UDA2182-CC1-NN2-NN-N-0E00-EE

The UDA2182 model is a universal dual-input analytical platform, and the CC1-NN2 configuration defines it as a single-input unit for contacting conductivity on Channel 1, with Channel 2 unused. It includes two 4–20 mA analog outputs for process control and two programmable alarm relays for safety and alert functions. This panel-mount unit supports non-invasive infrared communication for diagnostics and configuration, making it suitable for chemical, water treatment, and industrial utility monitoring. Built for durability and ease of use, the UDA2182 features a large LCD display, menu-driven interface, and flexible mounting options.

Key Features:

  • Single Input: Contacting Conductivity (CH1): Measures conductivity through precision sensors connected to input channel 1.
  • Dual 4–20 mA Analog Outputs: Provides scalable current loops for real-time control and monitoring.
  • Two Configurable Alarm Relays: Enables alerts or interlocks based on user-defined measurement thresholds.
  • Infrared Communications Port: Allows setup and diagnostics without direct electrical contact.
  • Panel Mount Design: Supports easy integration into control panels or instrument enclosures.
  • Dual-Channel Platform (CH2 Unused): Offers future expandability while maintaining single-input operation.
  • Menu-Driven Interface: Simplifies navigation and calibration via keypad and display.
  • Reliable for Harsh Environments: Suitable for industrial process applications like water treatment or chemical manufacturing.
  • Real-Time Measurement: High-speed data refresh for immediate process feedback.
  • Compact Footprint: Saves space while delivering full analytical control and output.

The UDA2182-CC1-NN2-NN-N-0E00-EE delivers robust, accurate conductivity analysis with integrated outputs and alarms, all within a scalable and easy-to-install form factor.

IQElectro is not an authorized distributor.
IQElectro LLC (IQElectro) is NOT an Authorized Distributor or in any way affiliated with Rockwell Automation, Siemens, or any other Manufacturers. IQElectro is NOT an Authorized Dealer of this product. The product may be of older version, date codes, or design than that available from authorized dealers. As IQElectro is not an authorized dealer of this product, the Original Manufacturer's Warranty and Support DO NOT apply. IQElectro sells SURPLUS only and DOES NOT SELL SOFTWARE or FIRMWARE licenses For more detailed information, please refer to the full version of our disclaimer policy Disclaimer Policy.
Description / Specifications

Description 

The Honeywell UDA2182-CC1-NN2-NN-N-0E00-EE is a single-channel analytical analyzer designed for precise conductivity measurement in industrial liquid analysis applications. It combines digital reliability with dual current outputs and integrated alarm functions in a compact panel-mounted design.

 

 

Technical Specifications 

Condition New/Never Used Surplus
Brand Honeywell
Category
Controls & Indicators
Part Number UDA2182-CC1-NN2-NN-N-0E00-EE
Subcategory Temperature/Process Control
Series UDA2182
Analyzer Type Single Input (Contacting Conductivity)
Channel 1 Input Contacting Conductivity
Channel 2 Input
None
Outputs (2) 4–20 mA analog outputs
Alarm Relays (2) SPDT programmable alarm relays
Communications Infrared (IR) diagnostics port
Mounting Type Panel Mount
Display LCD with menu navigation
Weight 2.59 lbs

  

 

Information About UDA2182-CC1-NN2-NN-N-0E00-EE

The UDA2182 model is a universal dual-input analytical platform, and the CC1-NN2 configuration defines it as a single-input unit for contacting conductivity on Channel 1, with Channel 2 unused. It includes two 4–20 mA analog outputs for process control and two programmable alarm relays for safety and alert functions. This panel-mount unit supports non-invasive infrared communication for diagnostics and configuration, making it suitable for chemical, water treatment, and industrial utility monitoring. Built for durability and ease of use, the UDA2182 features a large LCD display, menu-driven interface, and flexible mounting options.

Key Features:

  • Single Input: Contacting Conductivity (CH1): Measures conductivity through precision sensors connected to input channel 1.
  • Dual 4–20 mA Analog Outputs: Provides scalable current loops for real-time control and monitoring.
  • Two Configurable Alarm Relays: Enables alerts or interlocks based on user-defined measurement thresholds.
  • Infrared Communications Port: Allows setup and diagnostics without direct electrical contact.
  • Panel Mount Design: Supports easy integration into control panels or instrument enclosures.
  • Dual-Channel Platform (CH2 Unused): Offers future expandability while maintaining single-input operation.
  • Menu-Driven Interface: Simplifies navigation and calibration via keypad and display.
  • Reliable for Harsh Environments: Suitable for industrial process applications like water treatment or chemical manufacturing.
  • Real-Time Measurement: High-speed data refresh for immediate process feedback.
  • Compact Footprint: Saves space while delivering full analytical control and output.

The UDA2182-CC1-NN2-NN-N-0E00-EE delivers robust, accurate conductivity analysis with integrated outputs and alarms, all within a scalable and easy-to-install form factor.