VSP-015 | VESDA VLP Very Early Warning Aspirating Smoke Detector
- Regular price
- $939.00
- Sale price
- $939.00
- Regular price
-
Couldn't load pickup availability
Product Description P/N: VSP-015
Description
The VESDA VSP-015 (VLP Detector) by Honeywell is an advanced aspirating smoke detector engineered for very early warning fire detection. It continuously samples air through a network of pipes to detect smoke at the earliest stages of fire development. With an ultra-wide sensitivity range of 0.005%–20% obscuration/m, it ensures rapid, reliable detection for critical applications requiring maximum protection and minimal false alarms.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | Vesda (Honeywell International) |
| Category | Fire Safety |
| Part Number | VSP-015 |
| Subcategory | Aspirating Smoke Detector |
| Detection Technology | Laser-based optical sensing |
| Sensitivity Range | 0.005%–20% obscuration/m (0.0015%–6.25% obs/ft) |
| Alarm Levels | Four configurable levels: Alert, Action, Fire 1, Fire 2 |
| Number of Pipes | Four inlet pipes |
| Aspirator | High-efficiency fan with individual airflow monitoring per pipe |
| Airflow Supervision | Per sampling pipe |
| Network Interface | VESDAnet™ (fault-tolerant bi-directional communication) |
| AutoLearn™ Function | Automatic threshold learning during commissioning |
| Referencing | Compensates for external air pollution variations |
| Relays | Seven programmable relays |
| Event Log | Integrated event memory for alarm and fault history |
| Operating Voltage | 18–30 VDC nominal |
| Current Consumption | 420 mA (typical at 24 VDC) |
| Operating Temperature | 32°F to 120°F (0°C to 49°C) |
| Humidity Range | 10%–85% RH, non-condensing |
| Enclosure Material | Durable metal housing with replaceable air filter |
| Dimensions (H × W × D) | 7.0 × 8.0 × 10.0 in (178 × 203 × 254 mm) |
| Weight | 4 lbs (1.8 kg) |
| Approvals | UL, ULC, FM, LPCB, VdS, CE, ActivFire, NF-SSI, VNIIPO |
| Compliance Standards | EN 54-20 Class A, B, and C |
Information About VSP-015
The VSP-015 is part of the VESDA VLP Series, which serves as the core of the VESDA aspirating smoke detection (ASD) range. Utilizing a laser-based detection chamber, it provides exceptional sensitivity and stability across varying smoke concentrations. Airflow through each sampling pipe is continuously monitored by dedicated sensors, while VESDAnet™ communication ensures fault-tolerant networking between devices for seamless operation and configuration. The VLP includes advanced functions like AutoLearn™, which automatically adjusts alarm thresholds during commissioning, and Referencing, which compensates for environmental pollutants to reduce nuisance alarms. Its modular construction simplifies installation, servicing, and integration within complex fire protection networks.
Key Features:
- Ultra-Wide Sensitivity Range: Detects smoke concentrations from 0.005% to 20% obscuration/m for very early warning protection.
- Laser-Based Detection: Class 1 laser source and optical sensors provide highly accurate smoke particle measurement.
- Four Sampling Pipes: Supports up to four inlet pipes with individual airflow supervision for maximum coverage.
- AutoLearn™ Function: Automatically calibrates alarm thresholds during commissioning to adapt to the environment.
- VESDAnet™ Connectivity: Provides robust, fault-tolerant bi-directional communication between devices and modules.
- Referencing System: Compensates for external air contamination to minimize false alarms.
- Event Logging and Monitoring: Records alarm, fault, and service events for diagnostics and compliance tracking.
- Modular Design: Simplifies installation, replacement, and integration with external control and monitoring systems.
The VSP-015 delivers the reliability and precision required for high-sensitivity fire protection in mission-critical facilities such as cleanrooms, data centers, and industrial control environments.
Description
The VESDA VSP-015 (VLP Detector) by Honeywell is an advanced aspirating smoke detector engineered for very early warning fire detection. It continuously samples air through a network of pipes to detect smoke at the earliest stages of fire development. With an ultra-wide sensitivity range of 0.005%–20% obscuration/m, it ensures rapid, reliable detection for critical applications requiring maximum protection and minimal false alarms.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | Vesda (Honeywell International) |
| Category | Fire Safety |
| Part Number | VSP-015 |
| Subcategory | Aspirating Smoke Detector |
| Detection Technology | Laser-based optical sensing |
| Sensitivity Range | 0.005%–20% obscuration/m (0.0015%–6.25% obs/ft) |
| Alarm Levels | Four configurable levels: Alert, Action, Fire 1, Fire 2 |
| Number of Pipes | Four inlet pipes |
| Aspirator | High-efficiency fan with individual airflow monitoring per pipe |
| Airflow Supervision | Per sampling pipe |
| Network Interface | VESDAnet™ (fault-tolerant bi-directional communication) |
| AutoLearn™ Function | Automatic threshold learning during commissioning |
| Referencing | Compensates for external air pollution variations |
| Relays | Seven programmable relays |
| Event Log | Integrated event memory for alarm and fault history |
| Operating Voltage | 18–30 VDC nominal |
| Current Consumption | 420 mA (typical at 24 VDC) |
| Operating Temperature | 32°F to 120°F (0°C to 49°C) |
| Humidity Range | 10%–85% RH, non-condensing |
| Enclosure Material | Durable metal housing with replaceable air filter |
| Dimensions (H × W × D) | 7.0 × 8.0 × 10.0 in (178 × 203 × 254 mm) |
| Weight | 4 lbs (1.8 kg) |
| Approvals | UL, ULC, FM, LPCB, VdS, CE, ActivFire, NF-SSI, VNIIPO |
| Compliance Standards | EN 54-20 Class A, B, and C |
Information About VSP-015
The VSP-015 is part of the VESDA VLP Series, which serves as the core of the VESDA aspirating smoke detection (ASD) range. Utilizing a laser-based detection chamber, it provides exceptional sensitivity and stability across varying smoke concentrations. Airflow through each sampling pipe is continuously monitored by dedicated sensors, while VESDAnet™ communication ensures fault-tolerant networking between devices for seamless operation and configuration. The VLP includes advanced functions like AutoLearn™, which automatically adjusts alarm thresholds during commissioning, and Referencing, which compensates for environmental pollutants to reduce nuisance alarms. Its modular construction simplifies installation, servicing, and integration within complex fire protection networks.
Key Features:
- Ultra-Wide Sensitivity Range: Detects smoke concentrations from 0.005% to 20% obscuration/m for very early warning protection.
- Laser-Based Detection: Class 1 laser source and optical sensors provide highly accurate smoke particle measurement.
- Four Sampling Pipes: Supports up to four inlet pipes with individual airflow supervision for maximum coverage.
- AutoLearn™ Function: Automatically calibrates alarm thresholds during commissioning to adapt to the environment.
- VESDAnet™ Connectivity: Provides robust, fault-tolerant bi-directional communication between devices and modules.
- Referencing System: Compensates for external air contamination to minimize false alarms.
- Event Logging and Monitoring: Records alarm, fault, and service events for diagnostics and compliance tracking.
- Modular Design: Simplifies installation, replacement, and integration with external control and monitoring systems.
The VSP-015 delivers the reliability and precision required for high-sensitivity fire protection in mission-critical facilities such as cleanrooms, data centers, and industrial control environments.