The XP6-MA monitors up to six conventional detector zones, translating their status into addressable fire system signals w...  Read more
We accept:
  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Venmo
  • Visa
warranty
IQElectro 2-Year Warranty
Warranty for Product #: XP6-MA
IQElectro offers a free 2-year warranty on all products. You can trust that every purchase is a reliable investment in the future of your company. Warranty Terms
2-3 Day Free Shipping
Packed Ready to Ship
24/7 Expert Support
Return within 30-Days
IQElectro LLC BBB Business Review
IQElectro is Not an authorized distributor for Notifier
Original Manufacturer's Warranty Not Covered, This Product is SURPLUS.

Product Description P/N: XP6-MA

Description / Specifications

Description 

The Notifier XP6-MA is a six-zone interface module designed to monitor conventional two-wire detection circuits within addressable fire alarm systems. It supports Class A or Class B wiring and integrates with FlashScan® or CLIP communication protocols.

 

 

Technical Specifications 

Condition New/Never Used Surplus
Brand Notifier
Category
Safety Systems
Part Number XP6-MA
Subcategory Safety Relay
Input Circuits 6 Class B or 3 Class A initiating device circuits
Compatible Detectors Only listed two-wire detectors
Communication Protocol FlashScan® or CLIP
Addressing Method Rotary decimal switches
Status Indication Panel-controlled bicolor LEDs per circuit
Power Supply External, shared among circuits (supervised)
Unused Circuits Up to 2 may be disabled
Wiring Terminals Plug-in type, accepts 12–18 AWG (3.1–0.78 mm²)
Mounting Options
BB-XP, CHS-6 in CAB-3/4/BB-25/EQ cabinet series
Operation Modes CLIP or FlashScan-compatible panels
Dimensions 6.80 × 5.80 × 1.25 in
Weight 0.2 lbs

  

 

Information About XP6-MA

The XP6-MA enables seamless integration of conventional two-wire detection zones into Notifier’s intelligent fire alarm systems. Each module supports six Class B (or three Class A) initiating device circuits, making it suitable for retrofits or hybrid systems where existing conventional devices are retained. All circuits operate via a common signaling line circuit (SLC) and share a supervised external power supply and ground, ensuring unified status reporting and reliable supervision.

The XP6-MA reports three status conditions—normal, open, and alarm—for each detection zone, and features panel-controlled bicolor LEDs for visual indication per point. Up to two unused circuits can be selectively disabled, and addressing is done via rotary switches for easy configuration. Installation is flexible, supporting mounting in BB-XP, CHS-6 chassis, or CAB/EQ cabinet series. All terminal blocks are removable for quick wiring, and the unit is compatible with FlashScan or CLIP operation modes.

Key Features:

  • Six Supervised Input Zones: Supports six Class B or three Class A initiating circuits for conventional detectors.
  • Common SLC Bus Integration: Shares a single SLC address bus for streamlined wiring and communication.
  • Status Reporting: Monitors and reports normal, alarm, or open conditions per circuit to the FACP.
  • Rotary Addressing: Simplifies configuration with panel-compatible address switches.
  • FlashScan®/CLIP Operation: Fully compatible with intelligent panels using either communication protocol.
  • Panel-Controlled LEDs: Provides per-zone visual status via dual-color panel-controlled indicators.
  • Unused Circuit Disable Option: Allows deactivation of up to two unused circuits for streamlined addressing.
  • Modular Mounting Options: Fits in BB-XP cabinet or up to six modules on CHS-6 chassis in CAB-3, CAB-4, BB-25, or EQ cabinets.
  • Plug-in Terminal Blocks: Accepts 12–18 AWG wiring for fast installation and service.
  • UL-Listed Compatibility: Works only with two-wire detectors specifically listed for use with XP6 modules.

The XP6-MA provides a reliable and flexible bridge between conventional detection zones and modern addressable fire alarm systems with full supervision and streamlined installation.

 

IQElectro is not an authorized distributor.
QElectro LLC (IQElectro) is NOT an Authorized Distributor or in any way affiliated with Rockwell Automation, Siemens, or any other Manufacturers. IQElectro is NOT an Authorized Dealer of this product. The product may be of older version, date codes, or design than that available from authorized dealers. As IQElectro is not an authorized dealer of this product, the Original Manufacturer's Warranty and Support DO NOT apply. IQElectro sells SURPLUS only and DOES NOT SELL SOFTWARE or FIRMWARE licenses For more detailed information, please refer to the full version of our disclaimer policy Disclaimer Policy.
Description / Specifications

Description 

The Notifier XP6-MA is a six-zone interface module designed to monitor conventional two-wire detection circuits within addressable fire alarm systems. It supports Class A or Class B wiring and integrates with FlashScan® or CLIP communication protocols.

 

 

Technical Specifications 

Condition New/Never Used Surplus
Brand Notifier
Category
Safety Systems
Part Number XP6-MA
Subcategory Safety Relay
Input Circuits 6 Class B or 3 Class A initiating device circuits
Compatible Detectors Only listed two-wire detectors
Communication Protocol FlashScan® or CLIP
Addressing Method Rotary decimal switches
Status Indication Panel-controlled bicolor LEDs per circuit
Power Supply External, shared among circuits (supervised)
Unused Circuits Up to 2 may be disabled
Wiring Terminals Plug-in type, accepts 12–18 AWG (3.1–0.78 mm²)
Mounting Options
BB-XP, CHS-6 in CAB-3/4/BB-25/EQ cabinet series
Operation Modes CLIP or FlashScan-compatible panels
Dimensions 6.80 × 5.80 × 1.25 in
Weight 0.2 lbs

  

 

Information About XP6-MA

The XP6-MA enables seamless integration of conventional two-wire detection zones into Notifier’s intelligent fire alarm systems. Each module supports six Class B (or three Class A) initiating device circuits, making it suitable for retrofits or hybrid systems where existing conventional devices are retained. All circuits operate via a common signaling line circuit (SLC) and share a supervised external power supply and ground, ensuring unified status reporting and reliable supervision.

The XP6-MA reports three status conditions—normal, open, and alarm—for each detection zone, and features panel-controlled bicolor LEDs for visual indication per point. Up to two unused circuits can be selectively disabled, and addressing is done via rotary switches for easy configuration. Installation is flexible, supporting mounting in BB-XP, CHS-6 chassis, or CAB/EQ cabinet series. All terminal blocks are removable for quick wiring, and the unit is compatible with FlashScan or CLIP operation modes.

Key Features:

  • Six Supervised Input Zones: Supports six Class B or three Class A initiating circuits for conventional detectors.
  • Common SLC Bus Integration: Shares a single SLC address bus for streamlined wiring and communication.
  • Status Reporting: Monitors and reports normal, alarm, or open conditions per circuit to the FACP.
  • Rotary Addressing: Simplifies configuration with panel-compatible address switches.
  • FlashScan®/CLIP Operation: Fully compatible with intelligent panels using either communication protocol.
  • Panel-Controlled LEDs: Provides per-zone visual status via dual-color panel-controlled indicators.
  • Unused Circuit Disable Option: Allows deactivation of up to two unused circuits for streamlined addressing.
  • Modular Mounting Options: Fits in BB-XP cabinet or up to six modules on CHS-6 chassis in CAB-3, CAB-4, BB-25, or EQ cabinets.
  • Plug-in Terminal Blocks: Accepts 12–18 AWG wiring for fast installation and service.
  • UL-Listed Compatibility: Works only with two-wire detectors specifically listed for use with XP6 modules.

The XP6-MA provides a reliable and flexible bridge between conventional detection zones and modern addressable fire alarm systems with full supervision and streamlined installation.

 